Nonselective digital subtraction angiography. Compact contrast material bolus for improved image quality
C R Rees1, R Alvarado, J C Palmaz
1Department of Radiology, University of Texas Health Science Center, San Antonio 78229.
Abstract:
Digital subtraction angiography (DSA) examinations of major aortic branch vessels traditionally have been performed with aortic injections of dilute contrast material (70-150 mg I/mL) over approximately 2 seconds. This study examines a technique employing rapid boluses of undiluted contrast material (282-300 mg I/mL) in small volumes and compares the quality of the images to those obtained using conventional methods. Twenty intra-aortic DSA angiograms of the renal arteries were performed in 10 patients. In each patient, both compact bolus and conventional injections were performed. Injections of 12 or 15 mL of diatrizoate meglumine-60% at 30 mL/second (duration = 0.4 or 0.5 seconds) were compared with injections of 24 or 30 mL of diatrizoate meglumine-30% at 12 mL/second (duration = 2 seconds). Aside from injection technique and image projection, no other variables were altered, and the iodine loads were the same for the two injections in each patient. The images were paired and rated by four radiologists without knowledge of the technical parameters. The radiologists overwhelmingly preferred the images corresponding to the compact bolus technique (Chi-square analysis P less than .001). Visualization of the main renal arteries and the intrarenal branches was improved (P less than .001 for both). A reduction in misregistration artifact is suggested but not statistically significant. We conclude that image quality in nonselective, intra-arterial DSA can be improved without an increase in iodine dosage by the rapid administration of undiluted contrast material in small volumes.
Related Concept Videos
Compact Bone
Compact bone, also called cortical bone, is the denser, stronger of the two types of bone tissue. It is found under the periosteum and in the diaphyses of long bones, where it provides support and protection. The microscopic structural unit of compact bone is called an osteon, or haversian system. Each osteon is composed of concentric rings of calcified...
Compacting Factor test
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Quality Assurance