Related Experiment Video
Updated: Sep 21, 2026

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry (UPLC-MS)
Published on: March 14, 2013
geoRge: A Computational Tool To Detect the Presence of Stable Isotope Labeling in LC/MS-Based Untargeted Metabolomics
Jordi Capellades1,2,3, Miriam Navarro1,3, Sara Samino1,3
1Centre for Omic Sciences, Universitat Rovira i Virgili , Avinguda Universitat 1, 43204 Reus, Spain.
Abstract:
Studying the flow of chemical moieties through the complex set of metabolic reactions that happen in the cell is essential to understanding the alterations in homeostasis that occur in disease. Recently, LC/MS-based untargeted metabolomics and isotopically labeled metabolites have been used to facilitate the unbiased mapping of labeled moieties through metabolic pathways. However, due to the complexity of the resulting experimental data sets few computational tools are available for data analysis. Here we introduce geoRge, a novel computational approach capable of analyzing untargeted LC/MS data from stable isotope-labeling experiments. geoRge is written in the open language R and runs on the output structure of the XCMS package, which is in widespread use. As opposed to the few existing tools, which use labeled samples to track stable isotopes by iterating over all MS signals using the theoretical mass difference between the light and heavy isotopes, geoRge uses unlabeled and labeled biologically equivalent samples to compare isotopic distributions in the mass spectra. Isotopically enriched compounds change their isotopic distribution as compared to unlabeled compounds. This is directly reflected in a number of new m/z peaks and higher intensity peaks in the mass spectra of labeled samples relative to the unlabeled equivalents. The automated untargeted isotope annotation and relative quantification capabilities of geoRge are demonstrated by the analysis of LC/MS data from a human retinal pigment epithelium cell line (ARPE-19) grown on normal and high glucose concentrations mimicking diabetic retinopathy conditions in vitro. In addition, we compared the results of geoRge with the outcome of X(13)CMS, since both approaches rely entirely on XCMS parameters for feature selection, namely m/z and retention time values. To ensure data traceability and reproducibility, and enabling for comparison with other existing and future approaches, raw LC/MS files have been deposited in MetaboLights (MTBLS213) and geoRge is available as an R script at https://github.com/jcapelladesto/geoRge.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021