Related Experiment Videos

Pseudoepidemic of urinary tract infections due to Trichosporon beigelii

J Stone1, R Manasse

  • 1Department of Medicine, Memorial Hospital and Medical Center, Cumberland, Maryland 21502.

Insights

A Trichosporon beigelii pseudoepidemic in intensive care units was caused by contaminated urinary catheter drainage systems. Improved hygiene and disposable equipment successfully halted the outbreak, highlighting the importance of proper specimen collection protocols.

Area of Science:

  • Medical Mycology
  • Infectious Diseases
  • Intensive Care Medicine

Background:

  • Trichosporon beigelii is a fungus that can cause opportunistic infections.
  • Urinary tract infections are common in intensive care unit (ICU) patients, particularly those with Foley catheters.
  • Initial isolation of T. beigelii from ICU patients' urine suggested a potential infection outbreak.

Purpose of the Study:

  • To investigate the source of Trichosporon beigelii isolation in ICU patients.
  • To determine if T. beigelii represented a true infection or a contamination event.
  • To identify and implement control measures for the pseudoepidemic.

Main Methods:

  • Microbiological analysis of urine samples from ICU patients with Foley catheters.
  • Comparison of urine samples collected from different ports of the catheter drainage system.
  • Environmental sampling of collection and sampling supplies.
  • Implementation of enhanced hygiene protocols and equipment changes.

Main Results:

  • Trichosporon beigelii was isolated from 15 ICU patients with Foley catheters over a 12-month period.
  • T. beigelii was consistently isolated from the gravity drainage port but not the proximal sampling port, indicating contamination.
  • The fungus was also found on various items used for urine collection and sampling.
  • Implementing improved hygiene, staff training, and disposable collection equipment eradicated the pseudoepidemic.

Conclusions:

  • The observed isolation of Trichosporon beigelii represented a pseudoepidemic due to contamination of the urinary catheter drainage system, not true patient infection.
  • Contamination originated from the urine collection and sampling process.
  • Enhanced infection control measures, including staff education and use of disposable supplies, were effective in resolving the pseudoepidemic.

Related Concept Videos