Kidney Function Evaluation According to Percentage of Technetium-99m Capture With Addition of Correcting Factor for
1From the Department of Science Management, National Research Medical Center, Astana, Kazakhstan.
Objectives:
Assess the safety and accuracy of renal static scintigraphy with introduction of the amendment coefficient for decay of 99m metastable (Tc-99m) at the calculation formula of capture percent Technemec 99m.
Materials And Methods:
This study analyzes retrospectively the results of renal static scanning of 44 patients. Of this group of patients, 21 are Chornobyl Nuclear Power Station accident liquid ators who have arterial hypertension and chronic pyelonephritis. Renal scanning was carried out with Genesys EPIC single-photon emission computed tomography system. Calculation of the capture percent of the radiopharmaceutical Technemec 99m was executed in the standard way with introduction of the amendment coefficient Tc-99m to decay at the calculation formula of capture percentage Technemec.
Results:
Significant differences by standard calculation method took place in the both the Chornobyl Nuclear Power Station accident liquidators and persons who were not subjected to the influence of a small radiation dosage (P < .05).
Conclusions:
A small radiation dose did not affect kidney function (P > .05) with introduction of the amendment coefficient for decay of technetium 99m; therefore, static scintigraphy is a safe method for assessing kidney structure and morphology. Introduction of amendment for decay of Tc-99m allowed false positive results in 11.9% of renal function assessments for patients with arterial hypertension and kidney dysfunction (P < .05). Calculation of the specific capture percent of radiopharmaceutical on 1 cm2 of visualization of renal parenchyma enabled a 29% increase in renal function identification accuracy.
More Related Videos
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
10:54Preparation and Evaluation of 99mTc-labeled Tridentate Chelates for Pre-targeting Using Bioorthogonal Chemistry
Published on: February 4, 2017
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies VII: Vascular Imaging
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...