Multidimensional Mass Spectrometry Coupled with Separation by Polarity or Shape for the Characterization of
Bryan C Katzenmeyer1, Shayna F Hague1, Chrys Wesdemiotis1
1Department of Chemistry, The University of Akron , Akron, Ohio 44325, United States.
Abstract:
Mass spectrometry (MS) and tandem mass spectrometry (MS/MS) were interfaced with ultra-performance liquid chromatography (UPLC) and ion mobility (IM) separation to characterize a complex nonionic surfactant, consisting of a methylated glucose core (glucam) conjugated with poly(ethylene oxide) (PEO(n)) branches that were partially esterified with stearic acid to form ethoxylated glucam (PEO(n)-glucam) stearates. Reverse-phase LC-MS afforded fast separation according to polarity into five major fractions. Accurate mass measurements of the ions in the mass spectra extracted from these fractions enabled conclusive identification of six components in the surfactant, including PEO(n)-glucam mono-, di-, and tristearates as well as free and esterified PEO(n) as byproducts. MS/MS experiments provided corroborating evidence for the fatty acid content in each fraction based on the number of stearic acid losses observed. With IM-MS, the total surfactant ions were separated according to charge and shape into four distinct bands. Extracted mass spectra confirmed the presence of two disaccharide stearates in the surfactant, which were undetectable by LC-MS. PEO(n)-glucam tristearates were, however, not observed upon IM-MS. Hence, LC-MS and IM-MS unveiled complementary compositional insight. With each method, certain components were particularly well separated from other ingredients (by either polarity or shape), to be detected with confidence. Consequently, combined LC-MS and IM-MS offer a superior approach for the characterization of surfactants and other amphiphilic polymers and for the differentiation of similarly composed amphiphilic blends. It is finally noteworthy that NH4(+) charges minimized chemical noise in MS mode and Li(+) charges maximized the fragmentation efficiency in MS/MS mode.
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Tandem Mass Spectrometry
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...