Related Experiment Video
Updated: Mar 28, 2026

Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Using screen-based simulation of inhaled anaesthetic delivery to improve patient care
1Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, 02115, USA jphilip@partners.org.
Abstract:
Screen-based simulation can improve patient care by giving novices and experienced clinicians insight into drug behaviour. Gas Man(®) is a screen-based simulation program that depicts pictorially and graphically the anaesthetic gas and vapour tension from the vaporizer to the site of action, namely the brain and spinal cord. The gases and vapours depicted are desflurane, enflurane, ether, halothane, isoflurane, nitrogen, nitrous oxide, sevoflurane, and xenon. Multiple agents can be administered simultaneously or individually and the results shown on an overlay graph. Practice exercises provide in-depth knowledge of the subject matter. Experienced clinicians can simulate anaesthesia occurrences and practices for application to their clinical practice, and publish the results to benefit others to improve patient care. Published studies using this screen-based simulation have led to a number of findings, as follows: changing from isoflurane to desflurane toward the end of anaesthesia does not accelerate recovery in humans; vital capacity induction can produce loss of consciousness in 45 s; simulated context-sensitive decrement times explain recovery profiles; hyperventilation does not dramatically speed emergence; high fresh gas flow is wasteful; fresh gas flow and not the vaporizer setting should be reduced during intubation; re-anaesthetization can occur with severe hypoventilation after extubation; and in re-anaesthetization, the anaesthetic redistributes from skeletal muscle. Researchers using screen-based simulations can study fewer subjects to reach valid conclusions that impact clinical care.
More Related Videos
09:36Halogenated Agent Delivery in Porcine Model of Acute Respiratory Distress Syndrome via an Intensive Care Unit Type Device
Published on: September 24, 2020
15:04Modeling and Simulations of Olfactory Drug Delivery with Passive and Active Controls of Nasally Inhaled Pharmaceutical Aerosols
Published on: May 20, 2016
Related Concept Videos
Inhalational Anesthetics: Overview
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...