The Simulacrum System as a Construct for Mass Spectrometry of Triacylglycerols and Others
1Food Composition and Methods Development Lab, U.S.D.A. Agricultural Research Service, 10300 Baltimore Ave., Bldg. 161, Beltsville, MD, 20705, USA. C.Byrdwell@ars.usda.gov.
Abstract:
A construct called a simulacrum is defined that provides all possible solutions to a sum of two mass spectral abundances, based on values (abundances) or ratios of those values. The defined construct is applied to atmospheric pressure chemical ionization mass spectrometry (MS) of triacylglycerols (TAG). A simulacrum has precisely defined components, specifically a simulacrum sum, four Possibilities to Observe, two Cases, and eight solutions. A simulacrum with no restrictions is the First General Form of a Simulacrum. When one value is specified to be 1 (as in MS), the construct is called a Unit Simulacrum, also called the First Specified Form of a Simulacrum. When one value is 1 and no value can be greater than 1 (the two specifications dictated by mass spectrometry), the construct is called the Second Specified Form of a Simulacrum, or the Mass Spectrometry Simulacrum. Simulacra are used with three Critical Ratios calculated from raw abundances in mass spectra of TAG to provide structural information about the degree of unsaturation in TAG, the identity and quantity of regioisomers, and other structural characteristics. Three-level-deep nested simulacrum solutions yield the recently reported Updated Bottom Up Solution, from which the protonated molecule, [MH](+), and all diacylglycerol-like fragments, [DAG](+), of TAG can be reproduced from the Critical Ratios. Thus, the simulacrum solutions constitute a reduced data set in which more information is provided in fewer values than raw abundances, such that the Critical Ratios constitute a compact library of mass spectra.
More Related Videos
07:12Author Spotlight: Quantification of Complex Lipidomic Samples Using Stable Isotope Labeling
Published on: August 23, 2024
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
