Time domain simulations of preliminary breakdown pulses in natural lightning

B E Carlson1, C Liang2, P Bitzer3

  • 1Department of Physics, Carthage College Kenosha, Wisconsin, USA ; Birkeland Center for Space Science, University of Bergen Bergen, Norway.

Journal of Geophysical Research. Atmospheres : JGR
|December 15, 2015
PubMed

Related Concept Videos

Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
489
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
627
Lossy Lines and Overvoltages01:22

Lossy Lines and Overvoltages

Transmission-line series resistance and shunt conductance cause three primary effects: attenuation, distortion, and power losses.
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
386
Three-Phase Short Circuit—Unloaded Synchronous Machine01:21

Three-Phase Short Circuit—Unloaded Synchronous Machine

Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
812
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
484
Parallel RLC Circuits01:14

Parallel RLC Circuits

Street lamps equipped with RLC surge protectors are an excellent example of applying circuit analysis in practical scenarios. These surge protectors safeguard the lamp's components against sudden voltage spikes.
A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.
2.3K