[Development of Non-Contact Monitoring Device for Breathing and Heartbeat]
Abstract:
Physiological monitoring devices in modern clinical area are basically used electrodes or sensors directly touching the surface of human subject body, which will increase physiological and psychological load of the subjects. In order to realize non-contact monitoring of respiration and heartbeat, firstly, the micro bioradar was used to detect human body motion signal. Then, the respiration signal and heartbeat signal was extracted from the body-motion signal by using signal and conditioning circuits, digital filter and signal processing. Finally, the results of heart rate and breathing rate was wirelessly transmitted. The experimental results showed that the device for non-contact monitoring of respiration and heartbeat waveforms has advantages of small volume, low power consumption, which can realize the monitoring of physiological parameters in real time.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...