[Research on the Quantitative Analysis for In-Situ Detection of Acid Radical Ions Using Laser Raman Spectroscopy]
Abstract:
Laser Raman spectroscopy as an in situ analytical technology can enable detailed investigation of the ocean environment. It is necessary to set up a quantitative analysis method based on laser Raman spectroscopy to understand the marine status in situ. In the laboratory investigations, varied concentration of HCO3(-), SO4(2-) and coastal waters of Qingdao are taken as the samples, operating 532 nm of laser, using fiber optic probes to simulate detection mode in situ. Raman spectra are analyzed using the method of internal standard normalization, multiple linear regression (MLR), general Partial Least Squares (PLS) and PLS based on dominant factor respectively in data processing. It was found that correlation coefficients of calibration curves are not high in internal standard normalization method and predicted relative errors on the prepared samples are much high, so internal standard normalization method cannot be effectively used in the quantitative analysis of HCO3(-), SO4(2-) in the water. And with the multiple linear regression, the analysis accuracy was improved effectively. The calibration curve of PLS based on dominant factor showed that the SO4(2-) and HCO3(-) of pre-made solution with correlation coefficient R2 of 0.990 and 0.916 respectively. The 30 mmol · L(-1) of SO4(2-) and 20 mmol · L(-1) of HCO3(-) in two target samples were determined with the relative errors lower than 3.262% and 5.267% respectively. SO4(2-) in the coastal waters as the research object was analyzed by above-mentioned methods, comparing with 28.01 mmol · L(-1) by ion chromatography. It was demonstrated that PLS based on dominant factor method is superior to the rest of the three analysis methods, which can be used in situ calibration, with the mean relative error about 1.128%. All the results show that analysis accuracy would be improved by the PLS based on dominant factor method to predict concentration of acid radical ions.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...