Related Experiment Video
Updated: Mar 28, 2026

Use of a Video Scoring Anchor for Rapid Serial Assessment of Social Communication in Toddlers
Published on: March 14, 2018
A shortened verbal autopsy instrument for use in routine mortality surveillance systems
Peter Serina1, Ian Riley2, Andrea Stewart3
1Institute for Health Metrics and Evaluation, University of Washington, 2301 Fifth Ave., Suite 600, Seattle, WA, 98121, USA. ptserina@uw.edu.
Background:
Verbal autopsy (VA) is recognized as the only feasible alternative to comprehensive medical certification of deaths in settings with no or unreliable vital registration systems. However, a barrier to its use by national registration systems has been the amount of time and cost needed for data collection. Therefore, a short VA instrument (VAI) is needed. In this paper we describe a shortened version of the VAI developed for the Population Health Metrics Research Consortium (PHMRC) Gold Standard Verbal Autopsy Validation Study using a systematic approach.
Methods:
We used data from the PHMRC validation study. Using the Tariff 2.0 method, we first established a rank order of individual questions in the PHMRC VAI according to their importance in predicting causes of death. Second, we reduced the size of the instrument by dropping questions in reverse order of their importance. We assessed the predictive performance of the instrument as questions were removed at the individual level by calculating chance-corrected concordance and at the population level with cause-specific mortality fraction (CSMF) accuracy. Finally, the optimum size of the shortened instrument was determined using a first derivative analysis of the decline in performance as the size of the VA instrument decreased for adults, children, and neonates.
Results:
The full PHMRC VAI had 183, 127, and 149 questions for adult, child, and neonatal deaths, respectively. The shortened instrument developed had 109, 69, and 67 questions, respectively, representing a decrease in the total number of questions of 40-55%. The shortened instrument, with text, showed non-significant declines in CSMF accuracy from the full instrument with text of 0.4%, 0.0%, and 0.6% for the adult, child, and neonatal modules, respectively.
Conclusions:
We developed a shortened VAI using a systematic approach, and assessed its performance when administered using hand-held electronic tablets and analyzed using Tariff 2.0. The length of a VA questionnaire was shortened by almost 50% without a significant drop in performance. The shortened VAI developed reduces the burden of time and resources required for data collection and analysis of cause of death data in civil registration systems.
Related Concept Videos
SBAR II: Application of SBAR
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...
Kaplan-Meier Approach
Truncation in Survival Analysis
Left truncation occurs when individuals who experienced the event of interest before a certain time are not included in the study. This is often due to a "delayed entry" into the study where only those who survive until a certain entry point are...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Actuarial Approach
Consider the example of a high-risk surgical procedure with significant early-stage mortality. A two-year clinical study is conducted,...
Introduction To Survival Analysis
The primary goal of survival analysis is to estimate survival time—the time...

