Evaluation of load carriage systems used by active duty police officers: Relative effects on walking patterns and
Nerrolyn Ramstrand1, Roland Zügner2, Louise Bæk Larsen1
1School of Health Sciences, Jönköping University, Sweden.
Objectives:
This study aimed to examine the effects of two different load carriage systems on gait kinematics, temporospatial gait parameters and self-reported comfort in Swedish police.
Methods:
21 active duty police officers were recruited for this crossover study design. Biomechanical and self-report data was collected on two testing occasions. On occasion 1, three dimensional kinematic data was collected while police wore a/no equipment (control), b/their standard issues belt and ballistic protection vest and c/a load bearing vest with ballistic protection vest. Police then wore the load bearing vest for a minimum of 3 months before the second testing occasion.
Results:
The load bearing vest was associated with a significant reduction in range of motion of the trunk, pelvis and hip joints. Biomechanical changes associated with the load bearing vest appeared to reduce with increased wear time. In both the standard issue belt condition and the load bearing vest condition, police walked with the arms held in a significantly greater degree of abduction. Self-report data indicated a preference for the load bearing vest.
Conclusion:
The two load carriage designs tested in this study were found to significantly alter gait kinematics. The load bearing vest design was associated with the greatest number of kinematic compensations however these reduced over time as police became more accustomed to the design. Results from this study do not support selection of one load carriage design over the other and providing individuals with the option to choose a load carriage design is considered appropriate.
More Related Videos
06:58Method and Instrumented Fixture for Femoral Fracture Testing in a Sideways Fall-on-the-Hip Position
Published on: August 17, 2017
06:20Author Spotlight: Development of an Automated Camera-Based System for Real-Time Blast Overpressure Monitoring and TBI Risk Assessment in Military Training
Published on: December 6, 2024
Related Concept Videos
Design Consideration
The factor of safety is another key...
Applications of Stress
The...
Frames: Problem Solving I
Machines: Problem Solving II
Load along a Single Axis
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
Euler's Formula to Columns: Problem Solving
The system comprises two vertical rigid bars, AB and BC, of...