Effects of altitude changes on Doppler flow parameters for uterine, umbilical, and mid-cerebral arteries in term
Ayşe Nur Aksoy1, Gonca Batmaz2, Banu Dane2
1Department of Obsterics and Gynaecology, Nenehatun Maternity Hospital, Erzurum, Turkey.
Objective:
We hypothesized that maternal and fetal circulations may be affected by moderately high altitudes. Therefore, we compared the differences in maternal and fetal Doppler flow parameters in women with term pregnancy living at a moderately high altitude (1890 m in Erzurum) with those of women living at the sea level (31 m in İstanbul).
Material And Methods:
Eighty women (n=40, for each group) with full-term and singleton pregnancies underwent Doppler waveform analysis, and the pulsatility and resistance index values for the uterine, umbilical, and mid-cerebral arteries were recorded. Also, sex, birth, and placental weights during delivery were obtained from the medical records.
Results:
Similar mean placental weight values were found at the sea level compared with the moderately high altitude (p>0.05). The mean birth weight values were found to be lower at the moderately high altitude than those at the sea level (p<0.05). The pulsatility and resistance index values for the umbilical and mid-cerebral arteries were found to be similar between the groups (p>0.05). However, the pulsatility and resistance index values for both the right and left uterine arteries were higher at the sea level than those at moderately high altitude (p<0.05, for all).
Conclusion:
Moderately high altitude does not affect fetal vascular Doppler parameters. However, it appears to increase the uterine artery blood flow bilaterally, and these alterations in the bilateral uterine artery blood flow may be associated with a physiological adaptation to high altitude.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.