Estimating and reducing dose received by cardiac devices for patients undergoing radiotherapy
Alexandra Bourgouin1, Nicolas Varfalvy, Louis Archambault
1Université Laval. alex_8919@hotmail.com.
Abstract:
The objectives of this project are to quantify the dose reduction effect provided by a lead shield for patients with cardiac implantable electronic devices (CIED) during a clinically realistic radiation treatment on phantom and to provide a simple model of dose estimation to predict dose received by CIED in a wide range of situations. The shield used in this project is composed of a lead sheet wrapped in thermoplastic. Dose measurements were made with a plastic scintillation detector (PSD). The phantom was treated with ten different plans. Three of these cases were treated with intensity-modulated radiation therapy (IMRT) and the others received standard 3D conformal radiation therapy (3D CRT). Lateral dose measurement for photon fields was made to establish a dose prediction model. On average, the use of the lead shield reduced the dose to CIEDs by 19% ± 13%. Dose reduction was most important for breast cases, with a mean reduction of 31% ± 15%. In three cases, the total dose reduction was more than 25 cGy over the complete treatment. For the three IMRT cases, the mean dose reduction was 11% ± 9%. On average, the difference between the TPS prediction and the measurement was 71%, while it was only 14% for the dose prediction model. It was demonstrated that a lead shield can be efficiently used for reducing doses to CIED with a wide range of clinical plans. In patients treated with IMRT modality treatment, the shielding should be used only for those with more than two anterior fields over seven fields. In the case of 3D CRT patients, the shielding should be used for those with a dose on the CIED higher than 50 cGy and with a reduction of dose higher than 10 cGy. The dose prediction model developed in this study can be an easy way to have a better estimation of the out-of-field dose than the TPS.
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Dose Size and Dosing Frequency: Determination Methods
Imaging Studies for Cardiovascular System V: CT