Plate fixation of midshaft clavicular fractures: patient-reported outcomes and hardware-related complications
Micah Naimark1, Faustine L Dufka1, Richard Han1
1Department of Orthopaedic Surgery, University of California, San Francisco, San Francisco, CA, USA.
Background:
Recent studies report high hardware removal rates after plate fixation of midshaft clavicular fractures. Precontoured clavicle plates may decrease hardware-related complications while improving healing rates and patient-reported outcomes (PROs).
Methods:
Using a private-payer national database, we identified 7826 patients who underwent clavicle open reduction and internal fixation (ORIF) in 2007 to 2011. Database patients were tracked for 2 years to assess hardware removal and revision fixation. In addition, we retrospectively identified 73 patients who underwent plate fixation of midshaft clavicular fractures at our institution. These patients completed the Disabilities of Arm, Shoulder and Hand (DASH) assessment, the EQ-5D (EuroQol, Rotterdam, The Netherlands) quality of life assessment, and a hardware-related outcomes survey.
Results:
Among 7826 database patients, 994 (12.7%) underwent hardware removal and 78 (1%) required revision ORIF. The annual incidence of clavicle ORIF increased 61.5% between 2007 and 2011. In our institutional cohort, 56 patients (77%) were fixed with precontoured plates and 17 (23%) with standard plates. At a mean follow-up of 4.2 years, 11 patients (15%) underwent hardware removal and 1 patient (1.4%) experienced nonunion. Patients reported excellent outcomes, with average DASH of 4.0 ± 8.9 and EQ-5D of 0.89 ± 0.19. There were no differences in PROs, hardware removal, or union rate between plate types, although our study was underpowered for these outcomes. Patients who underwent hardware removal reported lower DASH, EQ-5D, satisfaction, and shoulder function compared with patients with hardware retained. Women were more likely to undergo hardware removal in the institutional (P = .009) and the database (P < .001) cohorts.
Conclusion:
Displaced midshaft clavicle fractures have high union rates with precontoured plate fixation. Women are 4 times more likely than men to have hardware removed. Patients undergoing clavicle hardware removal report worse long-term outcomes than patients with hardware retained.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
12:25C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
Related Concept Videos
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History:
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...