Related Experiment Video
Updated: Mar 28, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Estimation of late rectal normal tissue complication probability parameters in carbon ion therapy for prostate cancer
Mai Fukahori1, Naruhiro Matsufuji1, Takeshi Himukai2
1Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Japan.
Purpose:
The aim of this study was to estimate normal tissue complication probability (NTCP) parameters for late rectal complications after carbon ion radiotherapy (C-ion RT) for prostate cancer.
Methods And Materials:
A total of 163 patients were used to derive NTCP parameters. These patients were treated with relative biological effectiveness (RBE)-weighted dose ranging from 57.6 Gy (RBE) up to 72 Gy (RBE) and included in dose escalation trials. The Lyman-Kutcher-Burman (LKB) model was used and the model parameters were fit to the relation between dose and complication observed after C-ion RT.
Results:
The resulting NTCP parameters were the volume effect parameter; n=0.035 (95% CI: 0.024-0.047), the steepness of the NTCP curve; m=0.10 (0.084-0.13), the tolerance dose associated with 50% probability of complication; TD50=63.6 Gy (RBE) (61.8-65.4 Gy (RBE)) for Grade⩾1, n=0.012 (0.0050-0.023), m=0.046 (0.033-0.062), TD50=69.1 Gy (RBE) (67.6-70.9 Gy (RBE)) for Grade⩾2.
Conclusion:
A new set of rectal NTCP parameters in C-ion RT was determined. The rather small n values suggest that the rectum was consistent with being strictly serial organ. The new derived parameter values facilitate estimation of rectal NTCP in C-ion RT.