Non-Ventilator ICU-Acquired Pneumonia After Cardiothoracic Surgery: Accuracy of Diagnostic Tools and Outcomes

François Stéphan1, Youssef Zarrouki2, Christine Mougeot3

  • 1Cardiothoracic Intensive Care Unit f.stephan@ccml.fr.

Respiratory Care
|December 25, 2015
PubMed
Abstract

Insights

Diagnosing non-ventilator ICU-acquired pneumonia after cardiothoracic surgery is challenging. Fiberoptic bronchoscopy with bronchoalveolar lavage (FOB-BAL) is more sensitive than endotracheal aspirates (FOB-EA) for detecting this infection.

Area of Science:

  • Critical Care Medicine
  • Infectious Diseases
  • Thoracic Surgery

Background:

  • Non-ventilator ICU-acquired pneumonia (NV-ICUAP) poses diagnostic challenges in cardiothoracic surgery patients.
  • Limited data exist on the impact of NV-ICUAP on patient outcomes.
  • Accurate diagnosis is crucial for appropriate treatment and improved patient prognosis.

Purpose of the Study:

  • To compare the diagnostic accuracy of fiberoptic bronchoscopy with endotracheal aspirates (FOB-EA) versus bronchoalveolar lavage fluid (FOB-BAL) for NV-ICUAP.
  • To evaluate the utility of spontaneous sputum cultures and the modified Clinical Pulmonary Infection Score (CPIS).
  • To describe patient outcomes, including mortality and antibiotic use.

Main Methods:

  • A prospective observational study involving cardiothoracic surgery patients with suspected NV-ICUAP.
  • FOB-BAL cultures (≥10^4 cfu/mL) served as the reference standard.
  • Accuracy of FOB-EA (≥10^5 cfu/mL) and spontaneous sputum (≥10^7 cfu/mL) cultures were assessed.
  • Modified CPIS was determined on the day of FOB.

Main Results:

  • FOB-EA cultures demonstrated 82% sensitivity and 100% specificity, significantly less sensitive than FOB-BAL (P < .004).
  • Spontaneous sputum cultures (obtained in one-third of subjects) showed 82% sensitivity and 94% specificity.
  • The modified CPIS (>6) had low sensitivity (42%) but high specificity (87%) for diagnosing NV-ICUAP.

Conclusions:

  • Modified CPIS has limited diagnostic accuracy for NV-ICUAP.
  • FOB-EA cultures are less effective than FOB-BAL cultures for diagnosing NV-ICUAP.
  • Spontaneous sputum is a viable alternative when FOB is not feasible, though collection is limited.
  • Discontinuation of antibiotics is safe when cultures are negative.