Related Experiment Video
Updated: Mar 28, 2026

Substernal Thyroid Biopsy Using Endobronchial Ultrasound-guided Transbronchial Needle Aspiration
Published on: November 10, 2014
A Novel Technique for the Placement of Endobronchial Watanabe Spigots Into the Bronchus: Side-Grasping Method
Hirotaka Kida1, Hiromi Muraoka, Takeo Inoue
1Departments of *Internal Medicine †Respiratory Surgery, Division of Respiratory and Infectious Diseases, St. Marianna University School of Medicine, Kawasaki, Japan.
Background:
Bronchial occlusion with an endobronchial Watanabe spigot (EWS) is effective for the management of persistent pulmonary air leaks; however, an optimal procedure for placing the spigot at the target bronchus remains debatable. The procedure most currently applied involves grasping the middle of the graspable part of the EWS with grasping forceps (conventional method). In this study, we assess a new technique, the side-grasping method, to maneuver the spigot into the target bronchus by using rotatable biopsy forceps to grasp the edge of the graspable part of the EWS. The aim of this study is to evaluate the effectiveness of this new technique for the simple placement of the EWS.
Methods:
To compare the number of bronchoscopists who were able to place the EWS correctly within 10 minutes, and the time needed to place each spigot for both methods into 4 canine bronchi.
Results:
More bronchoscopists correctly placed the EWS within 10 minutes using the side-grasping method compared with the conventional method (35/40 vs. 15/40, P<0.01). The total time needed to place spigots into all bronchi using the side-grasping method was 13±2.2 minutes versus 27.8±3.6 minutes using the conventional method (P<0.01).
Conclusion:
The side-grasping method described in this study was a simple and effective technique for correctly placing an EWS spigot into the target bronchus.
More Related Videos
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...

