Background:
Tracheal intubation using Storz's C-Mac D-blade(TM) videolaryngoscope is associated with difficult negotiation of the tracheal tube into the glottis due to steep angulation of its blade.
Objectives:
In this study, we hypothesized that Truflex(TM) articulating stylet with its ability to dynamically tailor the ETT shape to patients' oropharyngeal anatomy would be better suited to the D-blade angulation and ease tracheal intubation compared to Portex(TM) intubation stylet.
Patients And Methods:
Following approval by the Ethical Issues Committee and informed consent, 218 ASA I and II patients of either sex were enrolled in this interventional, single-blind, randomized controlled trial. Tracheal intubation was performed following a uniform general anesthetic technique using the Storz's C-Mac D-blade(TM) videolaryngoscope aided by either Truflex(TM) articulating stylet or the Portex(TM) intubation stylet by an experienced anesthesiologist. The outcome measures included success or failure to intubate in the first attempt, total intubation time, hemodynamic disturbances, trauma if any and user satisfaction.
Results:
The number of patients in whom intubation was successful in the first attempt was significantly higher by using Truflex™ articulating stylet (99.1%) compared to Portex(TM) intubation stylet (90.0%; P-Value = 0.003). User satisfaction grade was significantly better while using Truflex(TM) articulating stylet (8.5 ± 0.88) compared to the Portex(TM) intubation stylet (8.23 ± 0.99; P-Value = 0.035). We did not observe any significant difference in total intubation time, hemodynamic disturbances or trauma.
Conclusions:
Storz's C-Mac D-blade(TM) videolaryngoscope provides grade I Cormack and Lehane's glottic view in 99.1% patients. First attempt successful tracheal intubation and user satisfaction significantly improved by Truflex(TM) articulating stylet compared to the Portex(TM) intubation stylet.
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Suctioning II: Procedure