Video Fluoroscopy for Positioning of Pulmonary Artery Catheters in Patients Undergoing Cardiac Surgery
Related Experiment Video
Updated: Mar 28, 2026

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Laurence Weinberg1, Lachlan F Miles2, Maysana Allaf2
1Department of Anesthesia, Department of Surgery and Centre for Anesthesia, Perioperative and Pain Medicine, The University of Melbourne, Victoria, Australia.
Objectives:
To determine whether video fluoroscopy combined with traditional pressure waveform analyses facilitates optimal pulmonary artery catheter (PAC) flotation and final positioning compared with the traditional pressure waveform flotation technique alone.
Design:
Prospective, single-center, randomized, controlled trial.
Setting:
Single-center university teaching hospital.
Participants:
The study included 50 cardiac surgery patients at higher risk for PAC complications.
Interventions:
Use of video fluoroscopy to facilitate optimal PAC flotation and positioning.
Measurements And Main Results:
The primary outcome was the time taken to float and position the PAC balloon in the pulmonary artery as confirmed by transesophageal echocardiography. Secondary outcomes included number of attempts at flotation, ventricular rhythm disturbances, and catheter malposition. Patients were evenly matched in baseline demographics, New York Heart Association symptoms of heart failure, severity of left and right ventricular dysfunction, end-diastolic pressures and dimensions, severity of tricuspid valvular disease, and atrial and pulmonary artery pressures. Mean (SD) time to float the PAC was significantly shorter in the video fluoroscopy group than in the usual care group: 73 seconds (SD, 65.1) versus 176 seconds (SD, 180.6), respectively; p = 0.014. The median (interquartile range [IQR]) number of attempts to successful flotation was fewer in the video fluoroscopy group than in the usual care group: 1 (IQR 1:2) attempt versus 2 (IQR 1:4) attempts, respectively; p = 0.007. The composite complication rate (malposition and arrhythmias) was lower in the video fluoroscopy group than in the usual care group (16% v 52%, respectively; p = 0.01).
Conclusions:
In cardiac surgery patients at higher risk for PAC complications, video fluoroscopy facilitated faster and safer catheter flotation and positioning compared with the traditional pressure waveform flotation technique.
More Related Videos
07:47The Supraclavicular Fossa Ultrasound View for Central Venous Catheter Placement and Catheter Change Over Guidewire
Published on: December 23, 2014
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization III: Left Heart Catheterization
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization II: Right Heart Catheterization
Imaging Studies for Cardiovascular System V: CT