Quicker response results in better SpO2 control - a comparison of 3 FiO2-titration strategies in ventilated preterm
Maria Wilińska1, Thomas Bachman2, Janusz Swietlinski3
1Medical Centre of Postgraduate Education, Warsaw, Poland.
Introduction:
The impact of SpO2 target ranges (TR) has been carefully studied; however, reports suggest a wide variation among infants and centres in maintaining the intended range. Little is known about the effectiveness of different approaches to manual control. Auto-SpO2 controllers are now available which show promise.
Objective:
The aim was to compare two different protocol-driven manual strategies with different response requirements to each other, and a faster automated system (AveaCLiO2, Yorba Linda, CA, USA).
Materials And Methods:
In a crossover design, each of the three FiO2/SpO2 approaches was implemented in three randomly assigned consecutive 2.5-hour runs. The two manual strategies (Attentive and Observational) were implemented by a trained operator. The primary endpoints were time in 1) SpO2 TR, 2) < 80% SpO2 and 3) >98% SpO2.
Results:
Fifteen studies were completed. All three approaches resulted in good control, with time in the target range >60%. CLiO2 use reflected reduced exposure at the two SpO2 extremes. Post hoc analysis determined that the differences were more marked in the infants with more frequent desaturations. Likewise, in this group, the Attentive strategy performed better than the Observative.
Conclusions:
All three approaches provided excellent control of SpO2 in infants with infrequent desaturations, significantly better than typical routine care. In hard to manage infants with frequent desaturations, faster response appeared to result in better control. The potential of automating the tedious error prone FiO2 adjustment offers significant promise. If manual titration of FiO2 is to remain the usual method of care, additional studies are needed to identify optimal approaches.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:27How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...