Abstract:
Heparin and related members of the glycosaminoglycan (GAG) family are highly polyanionic linear saccharides that play important roles in a variety of physiological processes ranging from blood coagulation to embryo- and oncogenesis, tissue regeneration, and immune response regulation. These diverse functions are executed via a variety of mechanisms, including protein sequestration, activation, and facilitation of their interactions with cell-surface receptors, but deciphering the specific molecular mechanisms is frequently impossible due to the extremely high degree of GAG heterogeneity. As a result, the vast majority of studies of heparin (or related GAGs) interactions with its client proteins use synthetically produced heparin mimetics with defined structure or short heparin fragments. In this work we use native electrospray ionization mass spectrometry (ESI MS) in combination with limited charge reduction in the gas phase to obtain meaningful information on noncovalent complexes formed by intact unfractionated heparin and antithrombin-III, interaction which is central to preventing blood clotting. Complexes of different stoichiometries are observed ranging from 1:1 to 1:3 (heparin/protein ratio). In addition to binding stoichiometry, the measurements allow the range of heparin chain lengths to be obtained for each complex and the contribution of each complex to the total ionic signal to be calculated. Incorporation of ion mobility measurements in the experimental workflow allows the total analysis time to be shortened very significantly and the charge state assignment for the charge-reduced species to be verified. The possibility to study interactions of intact unfractionated heparin with a client protein carried out directly by native ESI MS without the need to use relatively homogeneous surrogates demonstrated in this work opens up a host of new exciting opportunities and goes a long way toward ameliorating the persistent but outdated view of the intractability of such interactions.
More Related Videos
07:33Analyzing Protein Architectures and Protein-Ligand Complexes by Integrative Structural Mass Spectrometry
Published on: October 15, 2018
09:18Time-resolved ElectroSpray Ionization Hydrogen-deuterium Exchange Mass Spectrometry for Studying Protein Structure and Dynamics
Published on: April 17, 2017
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Tandem Mass Spectrometry
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Overview