Related Experiment Video
Updated: Mar 28, 2026

Catheter-based Endovascular Angioplasty for Fibrosing Mediastinitis-associated Pulmonary Vein Stenosis
Published on: August 26, 2025
Efficacy of the Stendo Pulsating suit in patients with leg lymphedema: a pilot randomized study
Patrick Jonas1, Stéphane Charlois1, Mélanie Chevalerias1
1Lymphology unit, CHIC Des Andaines Rue Sœur Marie Botier 61600 La Ferte Mace, France.
Background:
The "shear stress like" effect of pulsating suit sessions at 65 mm Hg (Stendo(®) device), evidenced in healthy volunteers, might stimulate venous return and act as a physiological pump in lymphedema patients.
Objectives:
To evaluate the lower limb total volume (TV) decrease induced by a pulsating suit versus intermittent pneumatic compression (IPC) sessions during a five-day complex decongestive physiotherapy (CDP) treatment.
Materials & Methods:
Twenty-four leg lymphedema patients were randomized into a CDP group according to the current practices and a CDP group where IPC was replaced by the pulsating suit. Daily care consisted of manual lymphatic drainage (MLD), one hour IPC or Stendo sessions, and bandaging. The Stendo inflatable suit generates heart rate synchronized compression/decompression applied to the lower part of the body. The IPC device was TP05/TP07 (Eureduc Company). Efficacy was assessed by leg TV changes after 5 days' CDP treatment.
Results:
TV decreases were more pronounced in the Stendo than the IPC group when adjusted to the baseline TV; TV decrease was 14.2 L (11.2%) in the Stendo group, 11.0 L (8.8%) in the IPC group (p = 0.052 - %TV change p = 0.08). A trend in improved quality of life was reported in favor of the Stendo group over the IPC groups (14.2% [SD: 23.4%] and 6.7% [SD:31.5%], respectively). No adverse event related to the Stendo device was reported.
Conclusion:
The promising Stendo results open the way to larger clinical studies targeting CDP maintenance and moderate lymphedema in outpatient settings.
More Related Videos
08:05Occlusion of the Great and Small Saphenous Vein Using Copolymeric Glue Based on N-Butyl Cyanoacrylate and Methacryloxy Sulfolane
Published on: December 9, 2022
09:38Minimally Invasive Isolated Limb Perfusion (MI-ILP) for Locally Advanced Melanomas and Sarcomas of the Extremity
Published on: January 31, 2025
Related Concept Videos
Peripheral Artery Disease V: Postoperative Nursing Management
Peripheral Artery Disease III: Interprofessional Care
Pulmonary Embolism III: Nursing Management
Peripheral Artery Disease IV: Nursing Management
Venous Thrombosis IV: Nursing Management
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...