Volar locking plate osteosynthesis for distal radial fractures
Saqib Javed1, Rizwan Shahid, Ravi Thimmiah
1Countess of Chester Hospital NHS Foundation Trust, United Kingdom.
Purpose:
To review the one-year outcome after volar locking plate fixation for distal radial fractures.
Methods:
Records of 22 men and 40 women aged 17 to 86 (mean, 52.5) years who underwent volar locking plate fixation for distal radial fractures were reviewed. According to the Fernandez classification, the distal radial fractures were classified as type 1 (n=20), type 2 (n=24), type 3 (n=6), type 4 (n=6), or type 5 (n=6). Three types of plate were used: Stryker Variax (n=33), Synthes LCP (n=20), and Smith & Nephew Peri-Loc (n=9). Wrist function was assessed at one year using the validated patient-rated wrist evaluation (PRWE) questionnaire.
Results:
14 (23%) of the 62 patients had 24 complications: stiffness (n=13), median nerve symptoms (n=4), malunion (n=2), implant removal for persistent pain and stiffness but no improvement shown (n=2), complex regional pain syndrome (n=2), and carpal arthritis (n=1). The complication rates for types 1, 2, 3, 4, and 5 fractures were 20%, 17%, 67%, 0%, and 33%, respectively (p=0.052). The complication rates for low-risk (types 1 and 2) and high-risk (types 3, 4, and 5) fractures were 18% and 33%, respectively (p=0.315). The complication rates for Stryker Variax, Synthes LCP, and Smith & Nephew Peri-Loc were 26%, 20%, and 14%, respectively (p=0.75). At one year, the mean PRWE score was comparable in patients with low-risk or high-risk fractures (14 vs. 19, p=0.5). 79%, 13%, and 8% of the patients recovered >50%, 20-50%, and <20% of range of movement of the contralateral side, respectively.
Conclusion:
Volar locking plate fixation followed by early rehabilitation for distal radial fractures achieved good outcome, with a low rate of implant-related complications.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
11:21Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation
Published on: March 13, 2026
Related Concept Videos
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Bones of the Upper Limb: Ulna
Bones of the Upper Limb: Humerus