Effect of Superficial Cervical Plexus Block on Baroreceptor Sensitivity in Patients Undergoing Carotid Endarterectomy
Serdar Demirel1, Juan Antonio Celi de la Torre2, Hans Bruijnen3
1Department of Vascular and Endovascular Surgery, University Hospital of Heidelberg, Heidelberg, Germany;.
Objectives:
Regional anesthesia for patients undergoing carotid endarterectomy is associated with improved intraoperative hemodynamic stability compared with general anesthesia. The authors hypothesized that the reported advantages might be related to attenuated ipsilateral baroreflex control of blood pressure, caused by chemical denervation of the carotid bulb baroreceptor nerve fibers.
Design:
A prospective cohort study.
Setting:
Single-center university hospital.
Participants:
The study included 46 patients undergoing carotid endarterectomy using superficial cervical block.
Interventions:
A noninvasive computational periprocedural measurement of baroreceptor sensitivity was performed in all patients. Two groups were formed, depending on the patients' subjective response to surgical stimulation regarding the necessity of additional intraoperative local anesthesia (LA) administration on the carotid bulb. Group A (block alone) included 23 patients who required no additional anesthesia, and group B (block + LA) consisted of 23 patients who required additional anesthesia.
Measurements And Main Results:
Baroreceptor sensitivity showed no significant change after application of the block in both groups (group A: median [IQR], 5.19 [3.07-8.54] v 4.96 [3.1-9.07]; p = 0.20) (group B: median [IQR], 4.47 [3.36-8.09] v 4.53 [3.29-8.01]; p = 0.55). There was a significant decrease in baroreceptor sensitivity in group B after intraoperative LA administration (median [IQR], 4.53 [3.29-8.01] v 3.31 [2.26-7.31]; p = 0.04).
Conclusions:
Standard superficial cervical plexus block did not impair local baroreceptor function, and, therefore, it was not related to improved cerebral perfusion in awake patients undergoing carotid endarterectomy. However, direct infiltration of the carotid bulb was associated with the expected attenuation of baroreflex sensitivity.
More Related Videos
07:46Bilateral Common Carotid Artery Occlusion as an Adequate Preconditioning Stimulus to Induce Early Ischemic Tolerance to Focal Cerebral Ischemia
Published on: May 9, 2013
06:30Quantifying Acute Changes in Renal Sympathetic Nerve Activity in Response to Central Nervous System Manipulations in Anesthetized Rats
Published on: September 11, 2018
Related Concept Videos
Neural Regulation of Blood Pressure
Baroreceptor Reflex
Baroreceptors, located in the carotid sinuses and aortic arch, detect changes in blood pressure. When blood pressure rises, these stretch-sensitive receptors...
Nondepolarizing (Competitive) Neuromuscular Blockers: Pharmacological Actions
Although all competitive neuromuscular blockers are designed...
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
Local Anesthetics: Differential Sensitivity of Nerve Fibers
Spinal Nerves: Plexus I
The Cervical Plexus
The cervical plexus, formed by the anterior rami of the first four...
Local Anesthetics: Clinical Application as Spinal Anesthesia