25-Hydroxyvitamin D assays: Potential interference from other circulating vitamin D metabolites
G D Carter1, J C Jones1, J Shannon1
1Charing Cross Hospital, Fulham Palace Road, London W6 8RF, UK.
Abstract:
The vitamin D External Quality Assessment Scheme (DEQAS) for 25-hydroxyvitamin D (25-OHD) has approximately 1100 participants in 53 countries using 26 different methods or variants of methods (October 2014). In April 2015, the scheme was extended to cover 24,25-dihydroxyvitamin D (24,25(OH)2D). Since 2013, the 25-OHD scheme has been accuracy-based with values assigned by the NIST reference measurement procedure (RMP). DEQAS is uniquely placed to assess the accuracy (bias) and specificity of 25-OHD methods in a routine laboratory setting. Other vitamin D metabolites are known to interfere in 25-OHD assays and DEQAS has distributed samples spiked with 3-epi-25-OHD3 (52.4nmol/L), 24R,25(OH)2D3 (14.4nmol/L) and 24S,25(OH)2D3 (57.9nmol/L). The 3-epimer showed a cross reactivity of 56% in a competitive protein binding assay but was not detected in any antibody-based methods. Not all HPLC/UV or LC-MS/MS methods were able to resolve 3-epi-25-OHD3 from 25-OHD3 and thus overestimated total 25-OHD. The cross reactivity of 24R,25(OH)2D3 (24S,25(OH)2D3) ranged from <5% (<5%) to 548% (643%) in ligand binding assays. Both 24-hydroxylated metabolites were resolved by HPLC/UV and LC-MS/MS methods and thus caused no complications in the measurement of 25-OHD. Most antibodies to 25-OHD are known to cross-react with dihydroxylated metabolites but interference in some assays was far greater than expected. This may be related to the anomalous behaviour of exogenously added metabolites in these 25-OHD methods.
More Related Videos
10:46A Method of Trigonometric Modelling of Seasonal Variation Demonstrated with Multiple Sclerosis Relapse Data
Published on: December 9, 2015
05:03Author Spotlight: Investigating Physiological Functions of Vitamin A Transporters Using HPLC-Based Vitamin A Profiling
Published on: December 27, 2024
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Role of Skin in Vitamin D Synthesis
The solar UV B rays (290-315 nm) are absorbed by the skin, and 7-dehydrocholesterol (provitamin D3) photolyzes it to previtamin D3, which undergoes a rapid transformation to vitamin...
Factors Affecting Protein-Drug Binding: Drug Interactions
Displacement interactions can have varying outcomes, ranging from toxicity to virtually...