Qualitative Comparison of Noncontrast Head Dual-Energy Computed Tomography Using Rapid Voltage Switching Technique
William D Hwang1, Mahmud Mossa-Basha, Jalal B Andre
1From the Department of Radiology, University of Washington Medical Center, Seattle, WA.
Objectives:
Dual-energy computed tomography (DECT) allows image reconstruction along a spectrum of virtual monochromatic energy levels. We sought to determine the optimal energy level(s) for viewing supratentorial brain and posterior fossa and compare those to polychromatic conventional CT (CCT). Furthermore, we compared 2 groups scanned with separate DECT imaging protocols. In addition, we quantify the radiation dose of DECT versus CCT.
Methods:
Forty-four nonacute patients underwent noncontrast DECT and recent CCT on the same scanner. Dual-energy CT images of the head were reconstructed at 5 keV intervals from 50 to 100 keV and randomized with CCT for blinded reader analysis. Evaluation of gray-white matter differentiation, posterior fossa artifact, and overall image noise was performed in consensus using a 5-point scale. In addition, the CTDIvol was compared with CCT examinations.
Results:
Optimal monochromatic viewing levels in evaluating gray-white matter differentiation were 50 to 55 keV and 50 to 60 keV, using regular-dose DECT (R-DECT) and low-dose DECT (L-DECT), respectively. The optimal levels for mitigating posterior fossa artifacts were 80 to 100 keV utilizing both R-DECT and L-DECT, whereas the optimal viewing levels for improved overall image noise were 60 to 65 keV and 65 to 70 keV for R-DECT and L-DECT, respectively. Readers favored both DECT techniques over CCT. The CTDIvol for DECT was 10% and 37% lower than CCT without a statistically significant reduction in image quality.
Conclusions:
Optimized noncontrast DECT compared favorably to CCT, with a significant dose reduction benefit.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET