HeartMate II Left Ventricular Assist Device Geometry on Chest Radiograph Does Not Correlate with Risk of Pump
Jason J Han1, Ann C Gaffey, Renganaden Sooppan
1From the *Division of Cardiovascular Surgery, Department of Surgery, University of Pennsylvania, Philadelphia, Pennsylvania; and †Division of Cardiovascular Medicine, Department of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania.
Abstract:
Pump thrombosis (PT) is a common and potentially life-threatening complication among HeartMate II (HMII; Thoratec, Pleasanton, CA) patients. There have been efforts to correlate HMII geometry with higher risk of PT. The aim of this study was to test the validity of using HMII inflow cannula angle (ICA) and pump pocket depth (PPD) to predict PT. We performed a retrospective analysis of patients implanted with HMII left ventricular assist devices (LVADs) from January 2011 to March 2014 at our institution. Three blinded reviewers measured ICA and PPD from chest x-rays at postimplantation and most recent follow-up time points. The diagnosis of PT was visually confirmed upon device explantation by benchtop evaluation. HeartMate II was implanted in 90 patients. Sixteen (20%) patients experienced PT. There was no statistical difference between PT and non-PT patients in their initial ICAs (56.0° ± 10.1 vs. 54.6° ± 10.8, p = 0.63) and PPD (86.7 ± 24.9 mm vs. 81.1 ± 32.2 mm, p = 0.46). Prediction of PT using ICA and PPD by receiving operating characteristic was negative (area under curve (AUC) = 0.54 and 0.55, respectively). Changes in HMII geometry were measured over 112.5 (interquartile range = 34.3-337.3) days. A decrease in PPD was observed (p = 0.0001). Initial ICA was a significant predictor of future angle change and suggested a convergence toward the mean (55.4°) (analysis of variance p = 0.002). Pump thrombosis recurred in four (25%) patients. Postoperative ICA and PPD do not appear to predict PT in HMII patients in our experience. HeartMate II geometry changes over time secondary to remodeling with a decrease in PPD and a convergence toward the median in ICAs. Further investigation into the role of geometric ventricular assist device conformation postimplant may be warranted.
Related Concept Videos
Mitral Stenosis II: Clinical features and Diagnostic Tests
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization