Related Experiment Video
Updated: Mar 28, 2026

A Detailed Protocol for Perspiration Monitoring Using a Novel, Small, Wireless Device
Published on: November 24, 2016
Inclusion of Height and Limb Length when Interpreting Sympathetic Skin Response
Mohamadreza Emad1, Sharareh Roshanzamir2, Alireza Dabbaghmanesh3
1Department of Physical Medicine and Rehabilitation, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
Abstract:
It is more than a decade since scientists are making use of sympathetic skin response (SSR) as a clinical and research method to evaluate sympathetic nervous system. A major portion of the efferent pathway of this response is composed of non-myelinated nerves. Thus, the latency of the response may be significantly different in normal individuals with different height and limb lengths. This study was designed to investigate the effect of these parameters on the SSR results. We measured the height and limb length of 65 normal individuals with different heights (divided into 3 groups of height ≤150 cm, 150-170 cm, and ≥170 cm). The participants had neither peripheral nor central neuropathy. They also had none of the exclusion criteria. Then, they underwent SSR testing of both palms and soles. The correlation between the height and limb length in relation to SSR parameters (latency and amplitude) was analyzed statistically by Pearson's correlation. No significant correlation was detected between the height and limb length and the SSR amplitude. However, the results showed significant correlation between SSR latency recorded from all four sites (both palms and soles) and the height of participants. Furthermore, there was a significant correlation between SSR latency recorded from any limb and the length of that limb. Regarding the significant effect of the height and limb length on the SSR latency, both the height and limb length should be considered when interpreting the results of SSR.
Related Concept Videos
Sympathetic Activation
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Sympathetic Pathways: Collateral Ganglia and Adrenal Medulla
Collateral Ganglia
Sympathetic preganglionic axons reach the collateral ganglia along the route of splanchnic nerves. These nerves bypass the sympathetic trunk and communicate with sympathetic postganglionic neurons housed in the prevertebral ganglia. These ganglia supply the organs of the abdominopelvic cavity.
The greater splanchnic nerve, formed by the...
Somatosensation