Related Experiment Video
Updated: Mar 28, 2026

Intratracheal Instillation of Stem Cells in Term Neonatal Rats
Published on: May 4, 2020
Effect of Minimally Invasive Surfactant Therapy on Lung Volume and Ventilation in Preterm Infants
Pauline S van der Burg1, Frans H de Jongh1, Martijn Miedema1
1Department of Neonatology, Emma Children's Hospital, Academic Medical Center, Amsterdam, The Netherlands.
Objective:
To assess the changes in (regional) lung volume and gas exchange during minimally invasive surfactant therapy (MIST) in preterm infants with respiratory distress syndrome.
Study Design:
In this prospective observational study, infants requiring a fraction of inspired oxygen (FiO2) ≥ 0.30 during nasal continuous positive airway pressure of 6 cmH2O were eligible for MIST. Surfactant (160-240 mg/kg) was administered in supine position in 1-3 minutes via an umbilical catheter placed 2 cm below the vocal cords. Changes in end-expiratory lung volume (EELV), tidal volume, and its distribution were recorded continuously with electrical impedance tomography before and up to 60 minutes after MIST. Changes in transcutaneous oxygen saturation (SpO2) and partial carbon dioxide pressure, FiO2, respiratory rate, and minute ventilation were recorded.
Results:
A total of 16 preterm infants were included. One patient did not finish study protocol because of severe apnea 10 minutes after MIST. In the remaining infants (gestational age 29.8 ± 2.8 weeks, body weight 1545 ± 481 g) EELV showed a rapid and sustained increase, starting in the dependent lung regions, followed by the nondependent regions approximately 5 minutes later. Oxygenation, expressed as the SpO2/FiO2 ratio, increased from 233 (IQR 206-257) to 418 (IQR 356-446) after 60 minutes (P < .001). This change was significantly correlated with the change in EELV (ρ = 0.70, P < .01). Tidal volume and minute volume decreased significantly after MIST, but transcutaneous partial carbon dioxide pressure was comparable with pre-MIST values. Ventilation distribution remained unchanged.
Conclusions:
MIST results in a rapid and homogeneous increase in EELV, which is associated with an improvement in oxygenation.
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Breathing
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Pulmonary Cycle: Exhalation
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...