Related Experiment Video
Updated: Mar 28, 2026

Simultaneous PET/MRI Imaging During Mouse Cerebral Hypoxia-ischemia
Published on: September 20, 2015
Concurrent functional and metabolic assessment of brain tumors using hybrid PET/MR imaging
1Department of Radiology, NYU School of Medicine, 660 First Avenue, 2nd Floor, New York, NY, 10016, USA.
Abstract:
To evaluate diagnostic accuracy of perfusion weighted imaging (PWI) and positron emission tomography (PET) using an integrated PET/MR system in tumor grading as well as in differentiating recurrent tumor from treatment-induced effects (TIE) in brain tumor patients. Twenty patients (Group A: treatment naïve, 9 patients with 16 lesions; Group B: post-therapy, 11 patients with 18 lesions) underwent fluorine 18 ((18)F) fluorodeoxyglucose (FDG) brain PET/MR with PWI. Two blinded readers predicted low versus high-grade tumor (for Group A) and tumor recurrence versus TIE (for Group B) based solely on tumor rCBV (regional cerebral blood volume) and SUV (standardized uptake values). Tumor histopathology at resection was the reference standard. Using rCBV(mean) ≤ 1.74 as a cut-off, 100% sensitivity and 74% specificity were observed, whereas 75% sensitivity and 89.7% specificity were observed with SUV(mean) ≤ 4.0 as a cut-off to classify patients as test positive for low-grade tumors (Group A) and TIE (Group B). Diagnostic accuracy for detection of low-grade tumors was 90% using PWI and 40% using PET in Group A (p = 0.056); for detection of TIE in Group B, diagnostic accuracy was 94.1% using PWI and 55.6% using PET (p = 0.033). No significant correlation was demonstrated between rCBV parameters and SUV in Group A (mean values: p > 0.403), Group B (p > 0.06) and in the entire population (p > 0.07). Best overall sensitivity and specificity were obtained using rCBV(mean) ≤ 1.74 and SUV(mean) ≤ 4.0 cut-off values. PWI demonstrated better diagnostic accuracy in both groups. Poor correlation was observed between FDG and rCBV parameters.
Related Concept Videos
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
Magnetic Resonance Imaging
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)
