Evaluation of Intraocular Pressure by Ocular Response Analyzer in Patients Undergoing Hemodialysis

Nilay Yuksel1, Necati Duru, Ebru Uz

  • 1Departments of *Ophthalmology †Nephrology, Yildirim Beyazit University, Ankara Ataturk Education and Research Hospital, Ankara, Turkey.

Journal of Glaucoma
|January 7, 2016
PubMed
Abstract

Related Concept Videos

Open Angle Glaucoma: Treatment01:27

Open Angle Glaucoma: Treatment

In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
1.1K
Hemodialysis III: Nursing Management01:25

Hemodialysis III: Nursing Management

The nursing management of a patient undergoing hemodialysis includes several critical steps, starting with a thorough assessment before the procedure.Before the Hemodialysis ProcedureFirst, record the patient's vital signs—blood pressure, heart rate, respiratory rate, and temperature—to establish a baseline. This baseline is essential for detecting conditions such as hypotension that could impact the patient's response to dialysis. Document the patient's pre-dialysis weight, as this...
1.5K
Glaucoma: Overview01:25

Glaucoma: Overview

Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
1.6K
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
1.7K
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate01:25

Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate

The glomerular filtration rate (GFR) is a critical indicator of kidney health, reflecting how well the kidneys filter blood. Changes in GFR can signal potential kidney impairment, necessitating accurate measurement methods to monitor kidney function effectively.Various molecules can serve as markers for GFR measurement, with the ideal marker meeting several specific criteria. It must freely filter at the glomerulus, avoid reabsorption or secretion by the renal tubules, remain unmetabolized, not...
102
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
2.9K