Fundamental analysis and development of the current and voltage control method by changing the driving frequency for
Abstract:
We have been developing transcutaneous energy transmission system (TETS) for a ventricular assist device, shape memory alloy (SMA) fibered artificial organs and so on, the system has high efficiency and a compact size. In this paper, we summarize the development, design method and characteristics of the TETS. New control methods for stabilizing output voltage or current of the TETS are proposed. These methods are primary side, are outside of the body, not depending on a communication system from the inside the body. Basically, the TETS operates at the fixed frequency with a suitable compensation capacitor so that the internal impedance is minimalized and a flat load characteristic is obtained. However, when the coil shifted from the optimal position, the coupling factor changes and the output is fluctuated. TETS has a resonant property; its output can be controlled by changing the driving frequency. The continuous current to continuous voltage driving method was implemented by changing driving frequency and setting of limitation of low side frequency. This method is useful for battery charging system for electrically driven artificial hearts and also useful for SMA fibered artificial organs which need intermittent high peak power comsumption. In this system, the internal storage capacitor is charged slowly while the fibers are turned off and discharge the energy when the fibers are turned on. We examined the effect of the system. It was found that the size and maximum output of the TETS would able to be reduced.
More Related Videos
14:47Author Spotlight: Combined Peripheral Nerve Stimulation and Controllable Pulse Parameter Transcranial Magnetic Stimulation to Probe Sensorimotor Control and Learning
Published on: April 21, 2023
13:29Electric and Magnetic Field Devices for Stimulation of Biological Tissues
Published on: May 15, 2021
Related Concept Videos
Load-frequency control
Control of Power Flow
Generator Voltage Control
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...