Related Experiment Video
Updated: Mar 27, 2026

Calculating Heart Rate Variability from ECG Data from Youth with Cerebral Palsy During Active Video Game Sessions
Published on: June 5, 2019
Estimation of heart rate from photoplethysmography during physical exercise using Wiener filtering and the phase
Abstract:
A system for estimation of the heart rate (HR) from the photoplethysmographic (PPG) signal during intensive physical exercises is presented. The Wiener filter is used to attenuate the noise introduced by the motion artifacts in the PPG signals. The frequency with the highest magnitude estimated using Fourier transformation is selected from the resultant de-noised signal. The phase vocoder technique is exploited to refine the frequency estimate, from which the HR in beats per minute (BPM) is finally calculated. On a publically available database of twenty three PPG recordings, the proposed technique obtains an error of 2.28 BPM. A relative error rate reduction of 18% is obtained when comparing with the state-of-the art PPG-based HR estimation methods. The proposed system is shown to be robust to strong motion artifact, produces high accuracy results and has very few free parameters, in contrast to other available approaches. The algorithm has low computational cost and can be used for fitness tracking and health monitoring in wearable devices.
More Related Videos
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Special considerations while measuring pulse
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...