Hemodynamics during Rotary Blood Pump support with speed synchronization in heart failure condition: A modelling study
Related Experiment Video
Updated: Mar 27, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Abstract:
The aim of this work is to study the hemodynamic changes in the cardiovascular system under different modes of Rotary Blood Pump (RBP) support. Continuous mode (constant pump speed) and co-pulse mode (increased pump speed in systole) are studied. Computer simulation studies have been conducted to evaluate the performances of these two modes under normal and pathological conditions. The pathological heart condition is simulated by reducing the maximum systolic elestance (Emax) in the cardiovascular system model. The model is implemented by using MATLAB Simulink. The pressure-volume loop of different heart conditions (normal heart: 100% of normal contractility, pathological heart: 30% of normal contractility) and the different modes of RBP support (8 krpm and 11 krpm in continuous mode, between 8 krpm and 11 krpm in co-pulse mode) are simulated. The results of this study show the slope of end systolic pressure volume relationship (ESPVR) changes in pathological condition. The reduction of area inside pressure volume loops depend on the increasing level of pump speed. The results indicated systolic aortic pressures in co-pulse mode are higher than in the continuous mode. In normal condition, the value of systolic aortic pressure in co-pulse mode is 113 mmHg and the values of systolic aortic pressures in continuous modes are 109 mmHg (8 k) and 95 mmHg (11 k). In pathological condition, the value of systolic aortic pressure in co pulse mode is 100 mmHg and the values of systolic aortic pressures in continuous modes are 90 mmHg (8 k) and 95 mmHg (11 k). The hemodynamics results of this study are comparable in vivo data, clinical data and other simulation studies. Therefore, this simulation enables hemodynamic studies in patients with end-stage heart failure, and patients under different modes of rotary blood pump support.
More Related Videos
08:21Functional Assessment of the Donor Heart During Ex Situ Perfusion: Insights from Pressure-Volume Loops and Surface Echocardiography
Published on: October 11, 2022
07:49Author Spotlight: Investigating HR-Dependent Cardiac Function in Mouse Models Through a Novel Atrial-Pacing Approach
Published on: July 21, 2023
Related Concept Videos
Heart Failure VI: Adjunct Therapies
Heart Failure V: Medical Management
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Heart Failure II: Pathophysiology
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: