Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Non-contact dual pulse Doppler system based respiratory and heart rates estimation for CHF patients
Abstract:
Long term continuous patient monitoring is required in many health systems for monitoring and analytical diagnosing purposes. Most of monitoring systems had shortcomings related to their functionality or patient comfortably. Non-contact continuous monitoring systems have been developed to address some of these shortcomings. One of such systems is non-contact physiological vital signs assessments for chronic heart failure (CHF) patients. This paper presents a novel automated estimation algorithm for the non-contact physiological vital signs assessments for CHF patients based on a patented novel non-contact biomotion sensor. A database consists of twenty CHF patients with New York Heart Association (NYHA) heart failure Classification Class II & III, whose underwent full Polysomnography (PSG) analysis for the diagnosis of sleep apnea, disordered sleep, or both, were selected for the study. The patients mean age is 68.89 years, with mean body weight of 86.87 kg, mean BMI of 28.83 (obesity) and mean recorded sleep duration of 7.78 hours. The propose algorithm analyze the non-contact biomotion signals and estimate the patients' respiratory and heart rates. The outputs of the algorithm are compared with gold-standard PSG recordings. Across all twenty patients' recordings, the respiratory rate estimation median accuracy achieved 92.4689% with median error of ± 1.2398 breaths per minute. The heart rate estimation median accuracy achieved 88.0654% with median error of ± 7.9338 beats per minute. Due to the good performance of the propose novel automated estimation algorithm, the patented novel non-contact biomotion sensor can be an excellent tool for long term continuous sleep monitoring for CHF patients in the home environment in an ultra-convenient fashion.
More Related Videos
07:49Author Spotlight: Investigating HR-Dependent Cardiac Function in Mouse Models Through a Novel Atrial-Pacing Approach
Published on: July 21, 2023
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse
Assessment of blood pressure in brachial artery(two-step method)
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...