Related Experiment Video

Updated: Mar 27, 2026

Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents
06:59

Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents

Published on: August 14, 2018

14.2K

Design and real-time control of a robotic system for fracture manipulation

G Dagnino, I Georgilas, P Tarassoli

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
    |January 7, 2016
    PubMed

    Abstract:

    This paper presents the design, development and control of a new robotic system for fracture manipulation. The objective is to improve the precision, ergonomics and safety of the traditional surgical procedure to treat joint fractures. The achievements toward this direction are here reported and include the design, the real-time control architecture and the evaluation of a new robotic manipulator system. The robotic manipulator is a 6-DOF parallel robot with the struts developed as linear actuators. The control architecture is also described here. The high-level controller implements a host-target structure composed by a host computer (PC), a real-time controller, and an FPGA. A graphical user interface was designed allowing the surgeon to comfortably automate and monitor the robotic system. The real-time controller guarantees the determinism of the control algorithms adding an extra level of safety for the robotic automation. The system's positioning accuracy and repeatability have been demonstrated showing a maximum positioning RMSE of 1.18 ± 1.14mm (translations) and 1.85 ± 1.54° (rotations).

    More Related Videos

    A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
    05:57

    A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique

    Published on: January 6, 2023

    3.9K
    Design and Implementation of a Bespoke Robotic Manipulator for Extra-corporeal Ultrasound
    07:41

    Design and Implementation of a Bespoke Robotic Manipulator for Extra-corporeal Ultrasound

    Published on: January 7, 2019

    9.7K

    Related Experiment Videos

    Last Updated: Mar 27, 2026

    Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents
    06:59

    Fracture Apparatus Design and Protocol Optimization for Closed-stabilized Fractures in Rodents

    Published on: August 14, 2018

    14.2K
    A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
    05:57

    A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique

    Published on: January 6, 2023

    3.9K
    Design and Implementation of a Bespoke Robotic Manipulator for Extra-corporeal Ultrasound
    07:41

    Design and Implementation of a Bespoke Robotic Manipulator for Extra-corporeal Ultrasound

    Published on: January 7, 2019

    9.7K

    Related Concept Videos

    Fractures: Bone Repair01:27

    Fractures: Bone Repair

    6.6K
    Treatment for a fracture is based on the type of break, the bone affected, and the patient's age.
    Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
    6.6K

    Articles linked to this work by shared authors, journal, and citation graph.

    Identification of Conduction Velocity of Bladder Afferent and Efferent Signals in the Sacral Roots of Sheep Using Cross-Correlation Methods.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Comparison between a multicentre, collaborative, closed-loop audit assessing management of supracondylar fractures and the British Orthopaedic Association Standard for Trauma 11 (BOAST 11) guidelines.

    The bone & joint journal·2018

    Computer hexapod-assisted orthopaedic surgery provides a predictable and safe method of femoral deformity correction.

    The bone & joint journal·2017

    Intra-operative 3D imaging system for robot-assisted fracture manipulation.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2016

    The medial approach for the treatment of children with developmental dysplasia of the hip.

    The bone & joint journal·2014

    Immediate loading rehabilitation of a severe oligodontia: minimum impact on a young patient's social life.

    Minerva stomatologica·2013

    Analysis of End-Tidal CO2 Variability During Plateau Waves Episodes: An Information Theoretic Approach.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    AI and Tomosynthesis for Breast Cancer Molecular Subtyping: A step toward precision medicine.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Towards Sustainable Protein Recovery from Biological Waste: Assessing Polyethersulfone-based Microfiltration.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Analysis of the cardiovascular response to standardized polymicrobial peritonitis experimental model.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Automated Wrist Ultrasound Image Bone Enhancement and Segmentation Using Deep Learning.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    A Deep Learning approach for Depressive Symptoms assessment in Parkinson's disease patients using facial videos.

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

    Fixed-time/predefined-time control for robotic systems with unknown system dynamics estimator.

    ISA transactions·2026

    De novo motor learning as controller synthesis: a conceptual framework.

    Biological cybernetics·2026

    Robot-assisted urologic surgery after kidney transplantation: indications, graft-protection strategies, and outcomes-a scoping review.

    Journal of robotic surgery·2026

    A Comprehensive General Model of Tendon-Actuated Concentric Tube Robots with Multiple Tubes and Tendons.

    IEEE transactions on medical robotics and bionics·2026

    Fast robot-to-iOCT calibration using conical geometry and 2D cross-scan OCT.

    Journal of biomedical optics·2026

    Robotic safety in self-driving laboratories.

    SLAS technology·2026
    See all related articles
    JoVE
    x logofacebook logolinkedin logoyoutube logo
    ABOUT JoVE
    OverviewLeadershipBlogJoVE Help Center
    AUTHORS
    Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
    LIBRARIANS
    TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
    RESEARCH
    JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
    EDUCATION
    JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
    Terms & Conditions of Use
    Privacy Policy
    Policies
    Jove
    Visualize
    Contact Us