Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
A chair for cuffless real-time estimation of systolic blood pressure based on pulse transit time
Abstract:
This study presents an unobtrusive cuffless blood pressure (BP) monitoring system for estimating beat-by-beat systolic blood pressure (SBP) in real-time based on pulse transit time (PTT). The system mainly includes an electrocardiograph with three conductive textile electrodes, a pulse monitor with a LED and a photodetector, a control circuit with a Bluetooth module, and a battery, all of which are mounted on a common armchair to measure ECG and photoplethysmography (PPG) signals from users during sitting on the armchair. The measured ECG and PPG data are transmitted to the software terminal installed on a tablet PC and are further derived to obtain a series of PTT for estimating beat-by-beat BP using Chen's method. We had 9 healthy subjects undergo the BP monitoring experiments of still sitting on a chair for 3 minutes, lying on a bed for 10 minutes, and pedaling using ergometer for 11 minutes in order to assess the accuracy of the estimated BP. A Finometer and a cuff-type BP meter were used as references in the experiments. Preliminary results showed that the mean error and mean absolute difference (MAD) of estimated BP were within -0.5 ± 5.3 mmHg and 4.1 ± 3.4 mmHg, respectively, compared to references. The result suggests that the proposed BP estimation system has the potential for long-term home BP monitoring.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure