Effects of serum indices interference on hormonal results from the Abbott Architect i2000 immunoassay analyser
Abstract:
The routine chemical assays are affected by sample haemolysis, icterus and lipaemia, collectively known as serum indices; however, little attention has been given to the consequences of these conditions on hormonal assays (immunoassays). In this study, we assess the impact of interferences from exogenous serum indices on various endocrine assays performed on the Abbott Architect i2000 system. The pool of 20 serum samples was derived from a hospitalised population. The diluted serum samples were spiked with red cell haemolysate, Intralipid and bilirubin. The interferences were studied at baseline; 12.5%, 25%, 50%, 75% and 100% of 5.0 g/L haemoglobin; 1% of 20% Intralipid; and 0.342 mmol/L of bilirubin according to the EP7-A2 guideline (Interference Testing in Clinical Chemistry; CLSI, USA). Aliquots were analysed in duplicate and/or triplicate for various hormones on the Abbott Architect i2000 immunoassay analyser. Serum ferritin (r2=0.84; P=0.074) and TSH (r2=0.81; P=0.52) levels showed a direct relationship with haemolysis and therefore overestimated because of the effects of haemolysis. The vitamin B12 level progressively decreased as the amount of haemolysis increased (r2=-0.76; P=0.136). There was a significant decrease in progesterone concentration owing to lipaemia (r2=-0.983; P=0.003). For icteric interferences, a strong inverse correlation was observed for folic acid and was shown to be statistically significant (r2=-0.94; P=0.017). Assays for ferritin, TSH, vitamin B12, folic acid and progesterone showed various degrees of interference because of the variability in serum indices.
More Related Videos
07:10Application of Biochip Microfluidic Technology to Detect Serum Allergen-specific Immunoglobulin E sIgE
Published on: April 21, 2019
08:26Development and Validation of an Ultrasensitive Single Molecule Array Digital Enzyme-linked Immunosorbent Assay for Human Interferon-α
Published on: June 14, 2018
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...