Related Experiment Video
Updated: Mar 27, 2026

Magnetic Resonance Imaging Assessment of Carcinogen-induced Murine Bladder Tumors
Published on: March 29, 2019
Performance of simultaneous high temporal resolution quantitative perfusion imaging of bladder tumors and
Nainesh Parikh1, Justin M Ream1, Hoi Cheung Zhang1
1Department of Radiology, NYU School of Medicine, NYU Langone Medical Center, 550 First Avenue, New York, NY 10016.
Purpose:
To investigate the feasibility of high temporal resolution quantitative perfusion imaging of bladder tumors performed simultaneously with conventional multi-phase MR urography (MRU) using a novel free-breathing continuously acquired radial MRI sequence with compressed-sensing reconstruction.
Methods:
22 patients with bladder lesions underwent MRU using GRASP (Golden-angle RAdial Sparse Parallel) acquisition. Multi-phase contrast-enhanced abdominopelvic GRASP was performed during free-breathing (1.4×1.4×3.0mm(3) voxel size; 3:44min acquisition). Two dynamic datasets were retrospectively reconstructed by combining different numbers of sequentially acquired spokes into each dynamic frame: 110 spokes per frame for 25-s temporal resolution (serving as conventional MRU for clinical interpretation) and 8 spokes per frame for 1.7-s resolution. Using 1.7-s resolution images, ROIs were placed within bladder lesions and normal bladder wall, a femoral artery arterial input function was generated, and the Generalized Kinetic Model was applied.
Results:
Biopsy/cystectomy demonstrated 16 bladder tumors (13 stage≥T2, 3 stage≤T1) and 6 benign lesions. All lesions were well visualized using 25-s clinical multi-phase images. Using 1.7-s resolution images, K(trans) was significantly higher in tumors (0.38±0.24) than normal bladder (0.12±0.02=8, p<0.001) or benign lesions (0.15±0.04, p=0.033). Ratio between K(trans) of lesions and normal bladder was nearly double for tumors than benign lesions (4.3±3.4 vs. 2.2±1.6), and K(trans) was nearly double in stage≥T2 than stage≤T1 tumors (0.44±0.24 vs. 0.24±0.24), although these did not approach significance (p=0.180-0.209), possibly related to small sample size.
Conclusion:
GRASP allows simultaneous quantitative high temporal resolution perfusion of bladder lesions during clinical MRU examinations using only one contrast injection and without additional scan time.
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies II: Ultrasonography
Imaging Studies VI: Voiding Cystourethrography and Cystography

