Using very high frequencies with very low lung volumes during high-frequency oscillatory ventilation to protect the
N González-Pacheco1, M Sánchez-Luna1, C Ramos-Navarro1
1Neonatology Division, Instituto de Investigación Sanitaria Hospital General Universitario Gregorio Marañón, Complutense University of Madrid, Madrid, Spain.
Objective:
High-frequency oscillatory ventilation (HFOV) has been described as a rescue therapy in severe respiratory distress syndrome (RDS) with a potential protective effect in immature lungs. In recent times, HFOV combined with the use of volume guarantee (VG) strategy has demonstrated an independent effect of the frequency on tidal volume to increase carbon-dioxide (CO2) elimination. The aim of this study was to demonstrate the feasibility of using the lowest tidal volume on HFOV+VG to prevent lung damage, maintaining a constant CO2 elimination by increasing the frequency.
Study Design:
Newborn infants with RDS on HFOV were prospectively included. After adequate and stable ventilation using a standard HFOV strategy, the tidal volume was fixed using VG and decreased while the frequency was increased to the highest possible to maintain a constant CO2 elimination. Pre- and post-PCO2, delta pressure and tidal volume obtained in each situation were compared.
Result:
Twenty-three newborn infants were included. It was possible to increase the frequency while decreasing the tidal volume in all patients, maintaining a similar CO2 elimination, with a tendency to a lower mean PCO2 after reaching the highest frequency. High-frequency tidal volume was significantly lower, 2.20 ml kg(-1) before vs 1.59 ml kg(-1) at the highest frequency.
Conclusion:
It is possible to use lower delivered tidal volumes during HFOV combined with VG and higher frequencies with adequate ventilation to allow minimizing lung injury.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Pulmonary Cycle: Exhalation
Breathing