Measurement and modeling of oxygen content in a demand constant mass ratio injection rebreather
Abstract:
Mechanical semi-closed rebreathers do not need oxygen sensors for their functions, thereby reducing the complexity of the system. However, testing and modeling are necessary in order to determine operational limits as well as the decompression obligation and to avoid hyperoxia and hypoxia. Two models for predicting the oxygen fraction in a demand constant mass ratio injection (DCMRI) rebreather for underwater use were compiled and compared. The model validity was tested with an IS-MIX, Interspiro AB rebreather using a metabolic simulator connected to a breathing machine inside a water-filled pressure chamber. The testing schedule ranged from 0.5-liter (L) to 3-liter tidal volumes, breathing frequencies from five to 25 breaths/minute and oxygen consumptions from 0.5 L/minute to 4 L/minute. Tests were carried out at surface and pressure profiles ranging to 920 kPa(a) (81 meters of sea water, 266 feet of sea water). The root mean squared error (RMSE) of the single-compartment model was 2.4 percent-units of oxygen for the surface test with the 30% dosage setting but was otherwise below 1% unit. For the multicompartment model the RMSE was below 1% unit of oxygen for all tests. It is believed that these models will aid divers in operational settings and may constitute a helpful tool when developing semi-closed rebreathing apparatuses.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...