Related Experiment Video
Updated: Jul 30, 2026

Milk Collection in the Rat Using Capillary Tubes and Estimation of Milk Fat Content by Creamatocrit
Published on: December 16, 2015
Automatic application of teat disinfectant through the milking machine cluster
1AFRC Institute for Animal Health, Compton Laboratory, Newbury, UK.
Abstract:
An automatic device, which infuses disinfectant into the mouthpiece of the liner of the milking machine cluster as teatcups are removed, is described. Application at this time avoids any delay in disinfection, reduces the workload in the parlour and increases reliability of application. The teats of 20 cows were contaminated before each milking by immersion in a suspension of Staphylococcus aureus and Streptococcus agalactiae and then disinfected manually or automatically with iodophor after milking. Str. agalactiae was recovered from less than 5% of swabs and there was no difference between the results from the two methods. Neither method of disinfection was as effective against Staph. aureus and the recovery rate was significantly greater for the automatic method for both swabs from teat barrel (P less than 0.05) and teat apex (P less than 0.001). Rates of intramammary infection for quarters automatically or manually disinfected were similar and low (3/40 v. 6/40 respectively). The automatic method facilitates cluster removal by relieving vacuum and decreasing frictional contact at the mouthpiece lip, and utilizes approximately half the quantity of disinfectant used by manual dipping (0.9 v. 1.9 ml/teat). However, iodine contamination in the milk from the iodophor teat disinfectant was significantly increased from 14.4 to 102.2 micrograms 12/100 ml milk when no backflushing was practised.
More Related Videos
09:59Application of the Intelligent High-Throughput Antimicrobial Sensitivity Testing/Phage Screening System and Lar Index of Antimicrobial Resistance
Published on: July 21, 2023
06:27Automated Hospital Room Disinfection Utilizing a Novel Aerosolized Hydrogen Peroxide Microdroplet Disbursing Technology
Published on: February 24, 2026
Related Concept Videos
Hand hygiene
Hand washing...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature
Automated Microbial Diagnostics