Purpose:
To prospectively evaluate the efficacy of a new three-dimensional gradient-echo sequence (Turbo LAVA) that uses undersampled k-space acquisition combined with a two-dimensional parallel imaging technique for hepatobiliary MRI.
Materials And Methods:
Sixty patients underwent T1-weighted gadoxetic acid-enhanced hepatobiliary axial MRI during a single breath-hold using both Turbo LAVA (thickness/interval=1.6/0.8mm) and conventional three-dimensional gradient-echo (4/2mm; LAVA) sequences at 3T. Axial 4-mm-thick reformation was performed from Turbo LAVA images. Portal vein-to-liver contrast (PLC), bile duct-to-liver contrast (BLC), and lesion-to-liver contrast (LLC) were compared. Two radiologists independently assessed image quality using a five-point scale. Sagittal 4-mm-thick multiplanar reconstructions (MPR) were performed from both sequences and assessed together with directly obtained 4-mm-thick sagittal LAVA images in terms of sharpness. The paired t-test was used to compare PLC, BLC, and LLC. The Wilcoxon signed rank test was used to compare five-point scales.
Results:
The mean PLC (P<0.001), BLC (P<0.001), and LLC (P<0.005) were significantly higher for Turbo LAVA than for LAVA; the scores for image noise and sharpness were inferior (P=0.000 and 0.005) and superior (0.005 and 0.157) for Turbo LAVA. There were no significant differences in the scores for bile duct visualization, artifacts, fat suppression quality, overall quality, and focal lesion conspicuity. For sagittal images, MPR Turbo LAVA showed significantly better sharpness than MPR LAVA but showed significantly worse sharpness compared with directly obtained LAVA.
Conclusion:
High-spatial-resolution single-breath-hold hepatobiliary MRI using Turbo LAVA was feasible. Diagnostic-quality MPR images can be obtained using this sequence.
Related Concept Videos
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies IV: Magnetic Resonance Imaging