Measurement of extremely (2) H-enriched water samples by laser spectrometry: application to batch electrolytic
L I Wassenaar1, B Kumar1, C Douence1
1International Atomic Energy Agency, Vienna International Center, A-1400, Vienna, Austria.
Rationale:
Natural water samples artificially or experimentally enriched in deuterium ((2) H) at concentrations up to 10,000 ppm are required for various medical, environmental and hydrological tracer applications, but are difficult to measure using conventional stable isotope ratio mass spectrometry.
Methods:
Here we demonstrate that off-axis integrated cavity output (OA-ICOS) laser spectrometry, along with (2) H-enriched laboratory calibration standards and appropriate analysis templates, allows for low-cost, fast, and accurate determinations of water samples having δ(2) HVSMOW-SLAP values up to at least 57,000 ‰ (~9000 ppm) at a processing rate of 60 samples per day.
Results:
As one practical application, extremely (2) H-enriched samples were measured by laser spectrometry and compared to the traditional (3) H Spike-Proxy method in order to determine tritium enrichment factors in the batch electrolysis of environmental waters. Highly (2) H-enriched samples were taken from different sets of electrolytically concentrated standards and low-level (<10 TU) IAEA inter-comparison tritium samples, and all cases returned accurate and precise initial low-level (3) H results.
Conclusions:
The ability to quickly and accurately measure extremely (2) H-enriched waters by laser spectrometry will facilitate the use of deuterium as a tracer in numerous environmental and other applications. For low-level tritium operations, this new analytical ability facilitated a 10-20 % increase in sample productivity through the elimination of spike standards and gravimetrics, and provides immediate feedback on electrolytic enrichment cell performance. Copyright © 2016 John Wiley & Sons, Ltd.
More Related Videos
14:11Quantification of Hydrogen Concentrations in Surface and Interface Layers and Bulk Materials through Depth Profiling with Nuclear Reaction Analysis
Published on: March 29, 2016
13:38Laser-Induced Fluorescence Emission L.I.F.E. as Novel Non-Invasive Tool for In-Situ Measurements of Biomarkers in Cryospheric Habitats
Published on: October 26, 2019
Related Concept Videos
Atomic Emission Spectroscopy: Lab
UV–Vis Spectrometers
Atomic Emission Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
High-Resolution Mass Spectrometry (HRMS)