A Strategy for Sensitive, Large Scale Quantitative Metabolomics
Published on: May 27, 2014
A Novel Strategy for Large-Scale Metabolomics Study by Calibrating Gross and Systematic Errors in Gas
Yanni Zhao1, Zhiqiang Hao2, Chunxia Zhao1
1Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences , Dalian 116023, China.
Abstract:
Metabolomics is increasingly applied to discover and validate metabolite biomarkers and illuminate biological variations. Combination of multiple analytical batches in large-scale and long-term metabolomics is commonly utilized to generate robust metabolomics data, but gross and systematic errors are often observed. The appropriate calibration methods are required before statistical analyses. Here, we develop a novel correction strategy for large-scale and long-term metabolomics study, which could integrate metabolomics data from multiple batches and different instruments by calibrating gross and systematic errors. The gross error calibration method applied various statistical and fitting models of the feature ratios between two adjacent quality control (QC) samples to screen and calibrate outlier variables. Virtual QC of each sample was produced by a linear fitting model of the feature intensities between two neighboring QCs to obtain a correction factor and remove the systematic bias. The suggested method was applied to handle metabolic profiling data of 1197 plant samples in nine batches analyzed by two gas chromatography-mass spectrometry instruments. The method was evaluated by the relative standard deviations of all the detected peaks, the average Pearson correlation coefficients, and Euclidean distance of QCs and non-QC replicates. The results showed the established approach outperforms the commonly used internal standard correction and total intensity signal correction methods, it could be used to integrate the metabolomics data from multiple analytical batches and instruments, and it allows the frequency of QC to one injection of every 20 real samples. The suggested method makes a large amount of metabolomics analysis practicable.
More Related Videos
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Propagation of Uncertainty from Systematic Error