Related Experiment Video
Updated: Aug 9, 2026

Murine Fetal Echocardiography
Published on: February 15, 2013
Accuracy of ultrasonic fetal weight estimation and detection of small for gestational age fetuses
P Palo1, R Erkkola, O Piiroinen
1Department of Obstetrics and Gynacology, University of Turku, Finland.
One hundred and eight-six pregnant women were studied with ultrasound for clinical suspicion of poor fetal growth. Fetal weight was estimated using biparietal diameter and mean abdominal diameter with a special nomogram. The fetal femur length (FL) to abdominal circumference (AC) ratio was also calculated. The mean interval between the last ultrasound examination and delivery was 9 days (range, 0 to 14 days). Eighty-three women had their last ultrasonic examination 0 to 4 days (mean, 2 days) before delivery. In this group the arithmetic mean of weight estimation errors was -1 gm (SD, 159 gm). The signed mean percent error was +0.6% (SD, 6.6%). Neither systematic nor random errors were found between different growth percentile groups. When small for gestational age (SGA) was defined as birthweight below 2.5 percentile, the sensitivity, specificity, and positive predictive value of the weight estimations were 82%, 92%, and 84%, respectively, in 186 cases. Significant differences were found in FL to AC ratios between growth pattern groups but fetal weight estimation was found to be superior in the detection of SGA fetuses.
One hundred and eight-six pregnant women were studied with ultrasound for clinical suspicion of poor fetal growth. Fetal weight was estimated using biparietal diameter and mean abdominal diameter with a special nomogram. The fetal femur length (FL) to abdominal circumference (AC) ratio was also calculated. The mean interval between the last ultrasound examination and delivery was 9 days (range, 0 to 14 days). Eighty-three women had their last ultrasonic examination 0 to 4 days (mean, 2 days) before delivery. In this group the arithmetic mean of weight estimation errors was -1 gm (SD, 159 gm). The signed mean percent error was +0.6% (SD, 6.6%). Neither systematic nor random errors were found between different growth percentile groups. When small for gestational age (SGA) was defined as birthweight below 2.5 percentile, the sensitivity, specificity, and positive predictive value of the weight estimations were 82%, 92%, and 84%, respectively, in 186 cases. Significant differences were found in FL to AC ratios between growth pattern groups but fetal weight estimation was found to be superior in the detection of SGA fetuses.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):

