Related Experiment Video
Updated: Mar 27, 2026

HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022
Stability-Indicating HPTLC Method for Studying Stress Degradation Behavior of Sulbutiamine HCl
Nehal F Farid1, Nada S Abdelwahab2
1Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Benisuef University, Benisuef, Egypt.
Abstract:
Sulbutiamine (SUL) is an ester of thiazides with neurotropic action. A new stability indicating HPTLC method has been developed and validated for the determination of SUL in the presence of different degradation products. The drug was subjected to different stress conditions following ICH strategy such as hydrolytic degradation (neutral, alkaline and acidic hydrolysis), oxidation, photodegradation and dry heat degradation. The drug demonstrated degradation under all decomposition conditions except neutral hydrolysis and dry heat, where the drug was completely degraded with 0.1 N NaOH, 1 N HCl and 30% H2O2 while it was partially degradaed by 0.1 N HCl, 3% H2O2 and UV light. Structure elucidation of the resulting degradation products was performed using ESI-Q-MS-MS. A well-defined peak for SUL was obtained at Rf = 0.46 and was completely separated from all obtained degradation products. Chromatographic separation was carried out on HPTLC aluminum plates precoated with silica gel 60 F254 using acetone-methylene chloride-ammonia buffer (pH 8.5 ± 0.2) (7:3:0.5, v/v) as a developing system. Densitometric scanning of the separated peaks was performed at 254 nm. System suitability testing parameters were calculated to ascertain the quality performance of the developed method. The method was validated with respect to USP guidelines regarding accuracy, precision, specificity, robustness and ruggedness. Good correlation coefficients were achieved in the range of 0.4-5.0 µg/band, and the limit of detection and limit of quantitation were found to be 0.11 and 0.33 µg/band, respectively. The utility of the suggested method was verified by application to Arcalion forte® tablets where no interference from additives was found.
More Related Videos
11:17Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
06:12Using Multiple Light Scattering to Examine the Stability of Phyllanthus emblica L. Extracts Obtained with Different Extraction Methods
Published on: April 14, 2023