Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
Assessment of Vascular Health With Photoplethysmographic Waveforms From the Fingertip
Abstract:
Although the flow-mediated dilation (FMD) index is considered the most reliable indicator of vascular endothelial function, previous studies have proved that the dilatation index (DI) measured by the highly reproducible air pressure sensing system (APSS) is just as accurate in effectively determining endothelial function. Besides, not only is APSS cheaper than the instrument for FMD ratio measurement, but operation of the former is also simple to facilitate its domestic use. However, APSS had the pitfall of being time consuming because of the large amount of computation involved. This paper attempted to validate a new self-developed endothelial function screening (EFS) device that utilized the photoplethysmography (PPG) system for acquiring PPG waveform signals from the index finger through an infrared sensor and a pressure cuff for applying pressure on ipsilateral upper arm for eliciting reactive hyperemic response to assess vascular health. The mean peak amplitude of the signals during the hyperemic phase was divided by that of the baseline to produce an EFS ratio. About 52 volunteers of age 34.76 ± 15.23 years without history of cardiovascular diseases were recruited for vascular endothelial function evaluation using the EFS device and the APSS. Bland-Altman analysis showed good consistency between the EFS ratio and DI. Besides, linear regression analysis demonstrated highly significant correlation between the two sets of data (p < 0.001, r2 = 0.6261) In conclusion, this paper, which attempted to validate a self-developed, economical, and time-efficient device that can be operated in a domestic setting, demonstrated that the EFS device yielded consistent results on vascular endothelial function comparable to those acquired through APSS.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pulse Assessment Sites
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation