Related Experiment Video
Updated: Mar 27, 2026

Measurement of Tumor T2* Relaxation Times after Iron Oxide Nanoparticle Administration
Published on: May 19, 2023
Accelerated exponential parameterization of T2 relaxation with model-driven low rank and sparsity priors (MORASA)
Xi Peng1,2, Leslie Ying3, Yuanyuan Liu1
1Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Shenzhen, Guangdong, China.
Purpose:
This work is to develop a novel image reconstruction method from highly undersampled multichannel acquisition to reduce the scan time of exponential parameterization of T2 relaxation.
Theory And Methods:
On top of the low-rank and joint-sparsity constraints, we propose to exploit the linear predictability of the T2 exponential decay to further improve the reconstruction of the T2-weighted images from undersampled acquisitions. Specifically, the exact rank prior (i.e., number of non-zero singular values) is adopted to enforce the spatiotemporal low rankness, while the mixed L2-L1 norm of the wavelet coefficients is used to promote joint sparsity, and the Hankel low-rank approximation is used to impose linear predictability, which integrates the exponential behavior of the temporal signal into the reconstruction process. An efficient algorithm is adopted to solve the reconstruction problem, where corresponding nonlinear filtering operations are performed to enforce corresponding priors in an iterative manner.
Results:
Both simulated and in vivo datasets with multichannel acquisition were used to demonstrate the feasibility of the proposed method. Experimental results have shown that the newly introduced linear predictability prior improves the reconstruction quality of the T2-weighted images and benefits the subsequent T2 mapping by achieving high-speed, high-quality T2 mapping compared with the existing fast T2 mapping methods.
Conclusion:
This work proposes a novel fast T2 mapping method integrating the linear predictable property of the exponential decay into the reconstruction process. The proposed technique can effectively improve the reconstruction quality of the state-of-the-art fast imaging method exploiting image sparsity and spatiotemporal low rankness. Magn Reson Med 76:1865-1878, 2016. © 2016 International Society for Magnetic Resonance in Medicine.
More Related Videos
Related Concept Videos
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Atomic Nuclei: Types of Nuclear Relaxation
In spin–lattice or longitudinal relaxation, the excited spins exchange energy with the surrounding lattice as they return to the lower energy level. Among several mechanisms that contribute to spin–lattice relaxation, magnetic dipolar interactions are significant. Here, the excited nucleus transfers...
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
Quadratic Models

